Using the GPIs / GPOs to Trigger Actions
After enabling E & M signaling on the E1 / T1 E-QUE cards, you can use the GPIs / GPOs associated with the configured ports to trigger actions.
For example, in the earlier example: Ship-to-shore satellite system:
-
The E & M signal from the shore-based communications system is forwarded by the matrix to the FOR-22 interface module. The FOR-22 module then generates relay closure for radio PTT (Push-to-Transmit).
-
An E & M signal is returned to the matrix to indicate that audio from the radio is being received.
To send E & M signals from the matrix to a ship’s radio, and to receive E & M signals in the matrix from the activated radio:
-
In EHX, select the appropriate matrix. Go to Configuration > Routes.
-
In Configuration > Routes, add two new routes:
-
Create a route from the first configured port on the E & M enabled E1 / T1 direct
E-QUE card to the first available port on the FOR-22 interface module.
Label the route (for the purposes of this example) Radio Out.
-
Create a route from the first available port on the FOR-22 interface module to the first configured port on the E & M enabled E1 / T1 direct E-QUE card.
Label the route (for the purposes of this example) Radio In.
-
-
In Configuration > Controls, add two new controls:
-
Label the first control PTT1.
-
Add the Radio Out route to PTT1.
-
Add the FOR-22 interface module relay / GPO (a relay associated with the FOR-22 port in the Radio Out route) to PTT1.
-
Note: This relay is used to trigger PTT at the ship’s radio.
-
Label the second control REC1.
-
Add the Radio In route to REC1.
-
Add the E & M relay / GPO (the relay associated with the first configured port on the E1 / T1 direct E-QUE card) to REC1.
Note: This relay receives the E & M signal from the ship’s radio into the matrix.
-
In Configuration > Cards and Ports > Matrix and Module GPIs:
-
Select the appropriate E & M enabled GPI (the GPI associated with the first configured port on the E1 / T1 direct E-QUE card).
-
In Advanced Settings, enable / select the trigger for the PTT1 control.
-
Note: When the E & M signal is received from the shore-based communications system at the E1 / T1 direct E-QUE card, the E & M signal is sent to the FOR-22 / radio.
-
In Configuration > System Ports:
-
Select the port for the FOR-22 interface module.
-
In Advanced Settings > VOX action, select the REC1 control from the drop-down menu.
-
In Advanced Settings > VOX action > Voice Op. Switch, adjust the Audio Off Delay and Audio Detect Threshold as required.
-
Note: When VOX is detected, the E & M signal for the FOR-22 / radio is sent via the E1 / T1 direct E-QUE card to the shore-based communications system.