Interconnecting intercom systems
You can connect FreeSpeak II Base to a range of intercom systems.
- Clear-Com Encore and RTS (2-wire cabled partyline systems)
- DX210 (2-wire/4-wire systems)
- Eclipse (digital matrix systems)
- HelixNet (digital partyline)
- Two-way radio systems
- FreeSpeak II Base can be connected to another FreeSpeak II Base station in order to share Channels between two Bases, increasing the range of your system.
| Note:
|
When connecting the base to other systems, you must connect the grounding screw to a good earth in order to prevent audio problems. |
When connecting FreeSpeak II Base to other intercom devices, the general process is the same, though there are details that change according to device type. As a general guideline you need to:
- Configure the relevant interface (port) settings (see below)
- Connect the device with CAT5 or microphone cable
- Adjust audio levels as required
When connecting 2-wire equipment the following functions should be taken into consideration:
- Auto-null. Every time equipment is changed on a 2-wire interface (port) you should run auto-null.
- Enable/disable the partyline power. Do this in Ports/2-Wire. Default setting: Disabled.
- Enable/disable Line termination. The line should only be terminated once on interconnected devices, do not terminate on more than one piece of equipment. Default setting: Disabled.
These functions can be set either in the 2-wire port settings page of the Core Configuration Manager (CCM) or from the front panel screens on the Base Station.
When connecting to 4-wire equipment the following need to be taken into account:
- To minimise noise, use screened (shielded) cable when connecting 4-wire ports.
- Pin-out configuration (mode) can be set on all FreeSpeak II Base 4-wire interfaces. This is a software switch that switches the configuration of the pins on the RJ45 connectors, according to the device you are connecting to. Default setting: To Matrix. See Port Function.