Was this helpful? We'd value your feedback! Click here...

 

Using LQ to interconnect equipment

When connecting LQ units to other Clear-Com products and third party intercom systems, use the following guidelines:

 

Device type Which LQ unit? To Panel/To Matrix (configure pinout in software) Supports call signaling? Panel data?
HelixNet  HLI-4W2 LQ-4W2LQ-R4W8LQ-R2W4-4W4  To panel Yes No
HelixNet  HLI-2W2(Note: this connection is not preferred for optimum audio quality) LQ-2W2LQ-R2W4LQ-R2W4-4W4LQ-R2W4-4WG4 N/A Yes No
MVX-A16/Eclipse PiCo LQ-4W2LQ-R4W8LQ-R2W4-4W4 To matrix(Identified as a CCI-22) Yes Yes
IVC-32 IP card/Clear-Com matrix LQ-2W2LQ-R2W4LQ-R2W4-4W4LQ-R2W4-4WG4   Yes Yes
Other matrices (third party) LQ-4W2LQ-R4W8LQ-R2W4-4W4  Depends on third-party pinout No

No

Encore MS-702/4 LQ-2W2LQ-R2W4LQ-R2W4-4W4LQ-R2W4-4WG4 N/A Yes No
Encore RS Beltpack 1/2/3 LQ-2W2LQ-R2W4LQ-R2W4-4W4LQ-R2W4-4WG4  N/A Yes No
RTS 2-wire equipment LQ-2W2LQ-R2W4LQ-R2W4-4W4LQ-R2W4-4WG4 N/A Yes, but does not pass call signaling to 4-wire audio routes. No
HME DX210/DX410 LQ-4W2 LQ-R4W8LQ-R2W4-4W4  LQ-2W2*LQ-R2W4*  To panel  Yes No
FreeSpeak/FreeSpeak II Base LQ-4W2LQ-R4W8LQ-R2W4-4W4 LQ-2W2*LQ-R2W4*  To panel Yes** No
V-Series panel i-Series panel   LQ-4W2LQ-R4W8LQ-R2W4-4W4   To panel Yes Yes
2-way radio or 4-wire device with relay activation LQ-4WG2LQ-R2W4-4WG4LQ-R4WG8 N/A Yes (call signal can fire relay) No

*This connection is not preferred for optimum audio quality. LQ-4W2 is recommended.

** On a FreeSpeak Base station, only ports 3 and 4 pass call signaling.

Table 1  Interconnection guidelines