ARCADIA CENTRAL STATION

Scalable 1RU intercom system core supporting a wide range of intercom user stations and interfaces.​

Details

Arcadia Central Station
  • Combined Wired and Wireless Intercom
  • Keypanels with Essential feature set
  • I.V. Direct Clear-Com Global Interfacing

            - LQ
            - Eclipse E-IPA
            - Arcadia

  • Local Dante and Analog Interfacing
  • CCM browser setup, configuration & monitoring
  • Scalable Licensed Port capacity
  • Front panel color touch screen with encoders for control and configuration
  • Plug-and-go central discovery and pairing
Capacity

FreeSpeak Wireless Intercom

  • (10) E1 Transceivers (1.91, 2.4 GHz)
  • (32) IP Transceivers (1.91, 5 GHz)
  • (64) Beltpacks2 (1.91, 2.4, 5 GHz)

HelixNet Wired Intercom

  • (24) Enabled Channels2, 3
  • (24) Powerline Devices
  • (128) User Stations (Beltpack, Speaker & Remote)

• V-Series4 Keypanel Essential Features

  • (32) AES67 Connected2, 4, 5
  • (≤32) I.V. Connected2, 3

• I.V. Direct Clear-Com Interface

  • (≤32) I.V. Direct Ports2

Dante Audio Network Interfaces

  • (64) Dante Ports2
Configuration
  • • (200) Licensed Ports2
    - FreeSpeak Beltpack
    – HelixNet Enabled Channel
    – V-Series Keypanel
    – I.V. Direct Port
    – Dante Port
  • (100) Channels
  • (100) Groups
  • (100) IFB5
  • (3005) Roles for FreeSpeak, HelixNet & V-Series
Connectivity
  • (8) Four-Wire - 1 for PGM/SA
  • (4) 2-Wire - 560mA per pair
  • (2) GPI Optically Isolated
  • (4) GPO Relay
  • (2) FreeSpeak E1 - RJ45/SFP switchable
  • (4) LAN - (2) RJ45, (2) SFP;Assignable to management (with HelixNet & I.V. Connectivity), AES67/AoIP, Dante Primary & Secondary

Footnotes:

11.9 GHz E1 and IPT transceivers should not overlap on the same system. Beltpacks will not roam between E1 and IPT Transceivers.
2Requires Arcadia with sufficient number of Licensed Ports
3Dependent on Device Allocation
4V-Series Iris and IrisX keypanels fully support all Arcadia features while original V-Series has limited support using I.V. ports. Non-Iris desktop panels can be configured using the 12 key 1RU Role layout. Non-Iris cannot be upgraded from Arcadia, requiring alternative methods. Expansion panels are not supported on Arcadia.
5 Available in Arcadia R4.1

Item Code

Arcadia with 4-pin Headset Connector

ARCADIA-X4-16P
ARCADIA-X4-32P
ARCADIA-X4-48P
ARCADIA-X4-64P
ARCADIA-X4-80P
ARCADIA-X4-96P
ARCADIA-X4-112P
ARCADIA-X4-128P
ARCADIA-X4-144P
ARCADIA-X4-160P
ARCADIA-X4-176P
ARCADIA-X4-192P
ARCADIA-X4-200P

Arcadia with 5-pin Headset Connector

ARCADIA-X5-16P
ARCADIA-X5-32P
ARCADIA-X5-48P
ARCADIA-X5-64P
ARCADIA-X5-80P
ARCADIA-X5-96P
ARCADIA-X5-112P
ARCADIA-X5-128P
ARCADIA-X5-144P
ARCADIA-X5-160P
ARCADIA-X5-176P
ARCADIA-X5-192P
ARCADIA-X5-200P

Licensed Port Upgrades

ARCADIA-8P-LIC
ARCADIA-16P-LIC

Includes: 

(1) Four-Wire PGM/SA Breakout Cable
(CAB-RJ45-PGM-SA)
(1) External PSU (PSU-EXT-001)

Optional Parts: 

GN-250-TRS: Gooseneck Microphone Short
GN-450-TRS: Gooseneck Microphone Long
SFP-MMFO-1G-SX: Multi-mode LAN SFP
SFP-SMFO-1G-LX: Single-mode LAN SFP
SFP-RJ45-1G: RJ45 LAN SFP
SFP-MMFO-100M-FX: Multi-mode E1 SFP
SFP-SMFO-100M-LX: Single-mode E1 SFP
HLI-MMFO: Multi-mode E1 SFP - Legacy
HLI-SMFO: Single-mode E1 SFP - Legacy
272G048-SP: PSU Mounting Bracket

Product
Description

FreeSpeak - Wireless Intercom

Arcadia supports the FreeSpeak family of wireless intercom, including 1.9 GHz, 2.4 GHz and 5 GHz frequency bands which can be concurrently deployed on an Arcadia system1. FreeSpeak antennatransceivers, connected via E1 CAT/Fiber plug and play cable connections, or networked via AES67capable networks, can be modularly added for coverage and capacity of beltpacks which roambetween transceivers. FreeSpeak beltpacks can have keys assigned to any FreeSpeak- or V-SeriesRole, Channel, Group, IFB or Interface Port. Each FreeSpeak beltpack requires an Arcadia Licensed Port2.​

HelixNet - Wired Partyline Intercom

Arcadia supports the HelixNet wired partyline intercom, including remote stations, speakerstations and beltpacks. Arcadia Channels can be selectively enabled for decentralized mixing inHelixNet User Stations. HelixNet user stations connect to Arcadia via an IP network or standard 3-pin XLR connection using the HelixNet powerline device allowing multiple stations to connect of apassively split line. HelixNet User Stations can have keysets and program audio level controlassigned to any HelixNet Enabled Channel on the Arcadia system. Each HelixNet Enabled Channelrequires an Arcadia Licensed Port2.

V-Series - Keypanel​

Arcadia supports the V-Series family of 12, 24 and 32 key panels with Essential features optimizedfor quick to deploy intercom. V-Series keypanels can connect to Arcadia locally via AES67 capablenetworks, or globally using Clear-Com’s Instant Voice I.V. connectivity. V-Series keypanels canhave keys assigned to any FreeSpeak- or V-Series Role, Channel, Group, IFB or Interface Port. Each V-Series keypanel requires an Arcadia Licensed Port2.​

I.V. Direct - Arcadia, LQ & Eclipse E-IPA Interfacing

Arcadia interfaces to LQ, Eclipse E-IPA or other Arcadia units locally & globally over LAN, WAN or Internetusing Clear-Com’s Instant Voice I.V. Direct ports. I.V. Direct port includes bi-directional audio and are easilyroutable through firewalls with adjustable network Quality-of-Service settings and security. I.V. Direct portsreceiving connection from LQ additionally include call and virtual GPIO control signaling available in theArcadia Logic configurator. I.V. Direct interface ports are assignable to any FreeSpeak- or V-Series Role,Channel, Group and IFB on the system. Each I.V. Direct port requires an Arcadia Licensed Port2.​

 

I.V. Direct provide Interface Expansion with LQ

  • 2-Wire & 4-Wire Interface with LQ 2 & 4-wire ports​

  • Two-Way Radio Interface with LQ GPIO ports​

  • SIP Interface on LQ with SIP License​

  • Agent-IC & Station-IC on LQ with License​

  • Gen-IC Virtual Intercom

 

I.V. Direct provide Intercom System Bridging

  • Eclipse-HX matrix with E-IPA (or IVC-32) IP card​

  • Arcadia Central Station​

  • Analog or 3rd Party Systems using LQ

Dante, Analog Audio & Control - Interfacing

Arcadia can interface to a variety of 3rd party audio and intercom systems with audio interface portsassignable to any FreeSpeak- or V-Series Role, Channel, Group and IFB on the system:​

  • Dante audio network interfaces allow any input or output to connect to Arcadia. Each Dante portrequires an Arcadia Licensed Port2.​

  • 4-Wire provides the ability to connect analog line-level audio inputs and outputs to Arcadia.​

  • 2-Wire Partyline allows interfacing to existing analog partyline intercom system infrastructures or to add Partyline devices using Arcadia’s built in power supply.​

  • GPIO provides Inputs and Relay Outputs for system control. Inputs allow activation of audiocrosspoints and call signals, while Outputs can be activated upon key presses, audio crosspointsand/or call signals configurable in Arcadia’s Logic configurator.

 

Intercom User Station

Arcadia’s front panel user station provides four keysets on color touch screens, assignable to any FreeSpeak- or V-Series Role, Channel, Group, IFB or interface on the system. The user station is provisioned with a loudspeaker, headset and gooseneck mic connection in addition to All Call, Stage Announce and Remote Mic Kill.

 

Configuration

Arcadia front panel facilitates basic system configuration. With the front panel, wireless components can be added, 2-Wire ports can be nulled and network addresses set. ​

Arcadia’s Core Configuration Manager™ (CCM) is an integrated, browser-based configuration configures Essential features optimized for quick to deploy intercom, configuration and monitoring.

 

Licensed Ports - Scalable Capacity

Arcadia allows capacity to be added as customer requirements grow or features are developed. Arcadia’s flexible licensing options allow right-sizing the system using Licensed Port capacity and expandable with field upgrades over time.​

 

 

 

 

 

 

 

 

 

 

11.9 GHz E1 and IPT transceivers should not overlap on the same system. Beltpacks will not roam between E1 and IPT Transceivers.
2Requires Arcadia with sufficient number of Licensed Ports

Technical
Specifications

Licenses

Delivery: License Ticket, may include multiple licenses
License Host: Arcadia
Activation: Via CCM, Online (recommended) or Offline
Transferable: No, fixed to Arcadia
Recovery: Yes, by Clear-Com Support or Service Center
 

Permanent Licenses
Part number:
ARCADIA-8P-LIC, ARCADIA-16PLIC
Capability: Additional 8 or 16 Licensed Port Upgrade Option
Validity: Perpetuity. Does not expire
Note: Licensed Port capacity is ordered with Arcadia. ARCADIA-8P-LIC and ARCADIA-16PLIC allow upgrade of Arcadia capacity in the field.

 
Connectors

Headset: 4-pin XLR-M (X4), 5-pin XLR-F (X5)

Gooseneck Microphone: ¼” TRS 7/16UNF-2A Threaded

2-Wire I/O: (4) XLR-3F

4-Wire I/O: (8) RJ45

Audio Crossover Mode: Software selectable; Special use of Port #8 using provided cable

Program input/ Stage output: XLR-3F, XLR-3M

GPIO: (2) DB9F (1 GPI, 2 GPO, 12V - each connector)

FSII E1 TCVR/SPL Ports: (2) RJ45, (2) SFP (RJ45 or SFP)

FSII DECT Synchronization: (2) RJ45 (Input and Output)

LAN: (2) RJ45, (2) SFP (Function assignable)

AC Power Connector: IEC-C14

DC Power Connector: KPJX-4S-S

Grounding Screw: Terminal

Note: While mechanically identical, SFPs are designed with different properties for data rates, power and fiber cable type. Please refer to the Clear-Com SFP Compatibility Chart for compatible SFP transceivers.

 

Controls and Indicators

Front Panel:
(2) Color Touch Screen Displays
(2) Power Supply Status LED
(1) Mic mute button
(1) Headset/Gooseneck Mic Input Select button
(1) Menu Access Button
(1) FN Button – For future use
(4) Encoders for Menu & Level Control
(1) Reset button - For service use 
(1) Speaker Mute LED
(1) Main Listen Level LEDs
Rear Panel:
(2) LAN RJ45 Link/Activity LEDs
(2) FSII E1 TCVR RJ45 Link/Activity LEDs
(4) 2-Wire Power / Configuration Indicator LEDs

 

Microphone Input

Input Type: Dynamic/Electret - Selectable

Headset Mic Voltage: 5V

Input Level (nominal): -45dBu

Input Level (max): -10dBu

Frequency Response: 200Hz to 12kHz ±3dB

Mic Limiter Threshold: -35dBu ±3dB

Mic Limiter Range: ≥ 20dB

 
Loudspeaker and Amplifier

Speaker: 1.6 x 2.8”

Load: 4Ω 

Max Speaker Level: 87dB ± 2dB SPL A at 3ft/1m

Frequency Response: 100Hz – 10kHz

Max Output Level before 1% Distortion: 18dBu ± 2dB

Total Harmonic Distortion (THD): < 0.5% THD at 1kHz

 

4-Wire Line Level Interfaces

Transformer balanced input and output

Input:

Nominal Level: 0dBu (adjustable -12dB to +12dB)

Maximum Level: +18dBu

Frequency Response: 80Hz to 20kHz ±3dB

Impedance: >= 10KΩ 

Output:

Nominal Level: 0dBu (adjustable -12dB to +12dB)

Maximum Level: +18dBu

Frequency Response: 80Hz to 20kHz ±3dB

Impedance: 200Ω + 10%

 

2-Wire Partyline Interfaces

Unbalanced High-Impedance bridging

Compatibility: Clear-Com, RTS-TW with Call and Remote Mic Kill

Termination: Optional per pair (A/B or C/D)

Nulling: User initiated Auto-Calibration

Null Depth: >60dB at 1kHz

Nominal Level: -18dBu (CC), -12dBu (RTS-TW)

Headroom: 18dB

Frequency Response: 200Hz to 12kHz. ±3dB

Impedance: >= 10KΩ bridging

Total Harmonic Distortion (THD): < 0.1% THD @ 1 kHz

Power: 560mA optional per pair (A/B or C/D)

Voltage: 25-28V DC

Use Encore Partyline Power Calculator to validate power requirements of the analog partyline intercom system

Frequency Response

Headset Mic: 200Hz to 12kHz
Gooseneck Mic: 200Hz to 12kHz
Speaker: 100Hz to 10kHz
Freespeak Edge: 200Hz to 12kHz
Freespeak II: 200Hz to 7.1kHz
HelixNet: 200Hz to 10kHz
I.V. Direct: 50Hz to 7.1kHz
Dante: 20Hz to 20kHz
4-Wire: 80Hz to 20kHz
2-Wire: 200Hz to 12kHz

 

Logic Power Output

To power Logic Inputs

Output Voltage: 12V, separate pin
Current (Max): 2mA

 

Logic Inputs - GPI

Assignable to activation of audio crosspoints or call

Input: 2
Style: Optically isolated
Input Voltage Range: 4 - 30V DC or AC
Input Current: >=1.2mA required

 
Logic Outputs – GPO / Relay

Assignable to talk, call keys and audio crosspoints or call

Outputs: 4
Style: SPDT / Power Relay
Normalized: Open or Closed, separate pins
Switching Voltage (Max): 30V DC
Switching Current (Max): 1A

 
Power

AC Internal Power Supply:
Input Frequency Range:
100 - 240V AC
Input Frequency Range: 50 - 60Hz
Input Power (Max): 160W
BTU (Max): 545BTU/h
Input Power Connector: IEC-C14
DC Power Input:
Voltage:
12V DC ± 5%
Current (Max): 12A
Power (Max): 144W
BTU (Max): 491BTU/hr
Input Power Connector: KPJX-4S-S
 

This unit can be powered via DC input using:

AC Adapter - Inline:
Type:
PSU-EXT-001 (supplied)
Mounting Bracket: 272G048 (optional)
Input Voltage Range: 100 - 240V AC
Input Frequency Range: 50 - 60Hz
Input Power Connector: IEC-C14
Output Voltage: 12V DC ± 5%
Output Current (Max): 12.5A
Output Power (Max): 150W
Output Power Connector: KPPX-4-P

 

Environmental

Operating: 32° to 113°F (0° to 45°C)

Storage: -22° to 158°F (-30° to 70°C)

Humidity: 20-90% Non-Condensing

 
Dimensions

1RU, 19 x 1.7 x 13.9in (WxHxD)

(482.6 x 43.2 x 353.1mm)

 
Weight

7.3lbs (3.3kg)